Calibration or Measurement Service |
Measurand Level or Range |
Measurement Conditions/Independent Variable |
|
Expanded Uncertainty |
|
|
|
||||||||||||
|
Quantity |
Instrument or Artifact: Measurand |
Instrument Type or Method |
Minimum value |
Maximum value |
Units |
Parameter |
Specifications |
Value |
Units |
Coverage Factor |
Level of Confidence |
Is the expanded uncertainty a relative one? |
NMI internal service identifier |
Comments |
|||||
|
Liquid volume flow |
Volumetric flowmeter |
Volume comparison (pulsed, electrical, digital and optical outputs) |
100 |
500 |
L/min |
Fluid |
gas-oil, kerosene, gasoline, heavy oil, diesel |
0.2 |
% |
2 |
95% |
Yes |
CU1 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pipe diameter |
50 mm |
|
|
|
|
|
|
|
|||||
|
Liquid volume flow |
Volumetric flowmeter |
Volume comparison (pulsed, electrical, digital and optical outputs) |
50 |
5E+03 |
L/min |
Fluid |
gas-oil, kerosene |
0.1 |
% |
2 |
95% |
Yes |
CU2 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pipe |
2 meter runs 50 mm and 100 mm |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Number of |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
reference |
4 |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
volumes |
|
|
|
|
|
|
|
|
|||||
|
Liquid volume flow |
Volumetric flowmeter |
Volume comparison (pulsed, electrical, digital and optical outputs) |
60 |
1.3E+03 |
L/min |
Fluid |
water |
0.2 |
% |
2 |
95% |
Yes |
CU3 |
Master meter Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pipe diameter |
75 mm |
|
|
|
|
|
|
|
|||||
|
|
|
Volume comparison |
|
|
|
|
|
|
|
|
|
|
|
Tank prover |
|||||
|
Liquid volume flow |
Volumetric flowmeter |
(pulsed, electrical, digital and optical |
50 |
2.5E+03 |
L/min |
Fluid |
water |
0.15 |
% |
2 |
95% |
Yes |
CU4 |
Approved on 08 November |
|||||
|
|
|
outputs) |
|
|
|
|
|
|
|
|
|
|
|
2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pipe diameter |
75 mm |
|
|
|
|
|
|
|
|||||
|
|
Glassware, pipettes, |
|
|
|
|
|
|
|
|
|
|
|
|
Approved on |
|||||
|
Static volume |
automatic pipettes, |
Gravimetric |
2E-03 |
50 |
L |
Liquid |
water |
0.02 to 0.008 |
% |
2 |
95% |
Yes |
CU5 |
08 November |
|||||
|
|
etc. |
|
|
|
|
|
|
|
|
|
|
|
|
2005 |
|||||
|
|
|
|
|
|
|
Temperature |
(20 ± 2)°C |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
atmospheric |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Approved on |
|||||
|
Static volume |
Micropipettes |
Gravimetric |
2E-02 |
5 |
mL |
Liquid |
water |
1 to 0.09 |
% |
2 |
95% |
Yes |
CU6 |
08 November |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2005 |
|||||
|
|
|
|
|
|
|
Temperature |
(20 ± 2)°C |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
atmospheric |
|
|
|
|
|
|
|
|||||
|
Static volume |
Metal or glass measure artefacts |
Gravimetric and volumetric |
1 |
5E+04 |
L |
Liquid |
water |
0.008 to 0.04 |
% |
2 |
95% |
Yes |
CU7 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
(20 ± 5)°C |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
atmospheric |
|
|
|
|
|
|
|
|||||
|
Static volume |
Storage tank (cylindrical standing) |
Geometric and volumetric |
10 |
5E+04 |
m3 |
Liquid |
any products at ambient temperature |
0.1 to 0.05 |
% |
2 |
95% |
Yes |
CU8 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Reference temperature |
15 °C or 20 °C |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
atmospheric |
|
|
|
|
|
|
|
|||||
|
Static volume |
Storage tank underground, road and rail tanks |
Volumetric |
1 |
1E+02 |
m3 |
Liquid |
water or diesel at ambient temperature |
0.5 to 1.0 |
% |
2 |
95% |
Yes |
CU9 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Reference temperature |
15 °C or 20 °C |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
atmospheric |
|
|
|
|
|
|
|
|||||
|
Gas volume flow |
Gas flow meters |
Sonic nozzles, turbine, laminar, P.D, rotameters |
5E-02 |
5 |
m3/h |
Gas |
dry air |
0.3 |
% |
2 |
95% |
Yes |
CU10 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
Gas volume flow |
Gas flow meters |
Sonic nozzles, turbine, laminar, P.D, rotameters |
5 |
50 |
m3/h |
Gas |
dry air |
0.2 |
% |
2 |
95% |
Yes |
CU10 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
|
|||||
|
Liquid volume flow |
Volumetric flowmeter |
Volume comparison (pulsed, electrical, digital and optical outputs) |
6.00E-01 |
6.6 |
m3/h |
Fluid |
gas-oil, kerosene, gasoline, heavy oil, diesel |
0.1 |
% |
2 |
95% |
Yes |
CU11 |
Approved on 08 November 2005 |
|||||
|
|
|
|
|
|
|
Temperature |
ambient |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
Pressure |
up to 0.8 MPa |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
Pipe diameter |
150 mm |
|
|
|
|
|
|
||||||
The BIPM key comparison database, February 2006